Function Call “=H2o.PTS(pressure, temperature, units, metastable)”

Input Parameters

Return Value

Default values: Units: (0)SI; Metastable: false

Metastable conditions may occur during a sudden steam expansion that crosses over from superheated to saturated conditions. The metastable calculations are valid from the saturated-vapor line to the 5% equilibrium moisture line for pressures from the triple-point pressure up to 10 MPa.

Reference Document: IAPWS R7-97